Measurement method of projectile explosion position based on two area array CCDs intersection and its error analysis
HANSHAN LI1,*
Affiliation
- School of Electronic and Information Engineering, Xi’an Technological University, Xi’an, 710021, China
Abstract
Because of the difference of the reflectance characteristic of the ground target and the detonation control of the projectile
fuze, the distribution of the projectile explosion position is an uncertain state in the falling process of the terminal trajectory, it
is relatively difficult to obtain the parameters of projectile explosion position. Combine with the characteristics of the test
environment, this paper proposes a new test and calculation method of projectile explosion position based on two area array
CCDs intersection by using the standard rod as the reference object, establishes the object-image relationship calculation
function of the standard rod in the CCD imaging system, and deduces the analytical model and calculation method of the
projectile explosion position according to the spatial intersection of the two area array CCDs and gives test method. In
addition, the paper sets up the error calculation model of projectile explosion position and analyses the influence of
uncertainty error factors under the engineering uncertainty testing. Through calculation and experiment analysis, the error
distribution of the test system is given, and the proposed test method and the computation model are verified.
Keywords
Area array CCD, Projectile explosion position, Standard rod, Intersection, Error analysis.
Citation
HANSHAN LI, Measurement method of projectile explosion position based on two area array CCDs intersection and its error analysis, Optoelectronics and Advanced Materials - Rapid Communications, 16, 5-6, May-June 2022, pp.228-235 (2022).
Submitted at: Oct. 25, 2021
Accepted at: June 6, 2022